特点 / Characteristi |
■ Adopting MEMS single crystal silicon flange diaphragm pressure chip imported from Germany
■ Wide Range Coverage
■ Two wire system, 4-20mA HART ® Protocol digital communication
■ Intelligent LCD monitor with backlight
■ Both remote transmission and local zero and range adjustment
■ Complete variety, high precision, and good stability
■ Explosion
proof shell structure with strong resistance to frequency conversion
interference
■ No mechanical transmission components, sturdy and vibration resistant
Purpose and Industry
■Process control fields in industries such as petroleum, chemical, metallurgy, electricity, food, papermaking, pharmaceuticals, mechanical manufacturing, scientific experiments, and aviation and military
be careful:
1. Do not touch the diaphragm with hard objects as it may cause damage to the isolation diaphragm.
2. Before installation, please carefully read the product manual and verify the relevant information of the product.
3. Strictly follow the wiring method, otherwise it may cause product damage and other potential faults.
4. Incorrect use can lead to danger and personal injury.
Product overview |
The internal chip of the HY-2004S monocrystalline silicon pressure transmitter adopts a MEMS monocrystalline silicon pressure chip imported from Germany. The sensor signal is converted into a standard signal output through a dedicated signal processing module. After long-term aging and stability screening, the product performance is stable and reliable, and it is applied to outdoor sites with relatively poor environments. At the same time, it can display on-site pressure, zero point, and full range migration.
The HY-2004S monocrystalline silicon pressure transmitter installation interface form can be processed according to user requirements, and can also provide specifications compatible with other brands of transmitters. This series of products is widely used in industrial process control, petroleum, chemical, metallurgical and other industries.
be careful:
1. Do not misuse the file.
The information in this selection is for reference only and cannot be used as a product installation guide.
Complete installation, operation, and maintenance information is provided in the product manual.
Incorrect use can lead to danger and personal injury.
Specification |
performance parameter | ||||
Range range | 0~1kPa…20MPa | |||
pressure type | Gauge pressure, absolute pressure | |||
Power supply transmission | 4~20mA@HART | |||
Zero temperature drift | ±0.3%FS/55℃ | |||
sensitivity temperature drift | ±0.5%FS/55℃ | |||
ambient temperature | -30℃~80℃; | |||
medium temperature | -40℃~104℃ | |||
storage temperature | -40℃~85℃ | |||
insulation resistance | ≥100MΩ/500VDC( 200MΩ/250VDC) | |||
mechanical vibration | 20g(20~5000Hz) | |||
impact | 100g(11ms) | |||
accuracy | 0.075%FS | |||
Overload pressure | See range selection | |||
Long term stability | ±0.2%FS/yeas | |||
protection grade | IP65 | |||
Explosion proof level | Exd II BT6 Gb | |||
texture of material | Low copper aluminum alloy shell; Isolation diaphragm 316L, Hastelloy C, tantalum | |||
media compatibility | Various media compatible with 316L stainless steel | |||
response time | ≤1ms |
Component diagram
HART Communication Connection Diagram
Overall dimensions
Threaded interface | ||
Thread code | C1:M20×1.5-6g | C2:G1/2 |
Dimensional drawing units:mm |
|
|
Recommended torque | 15~25Nm | 15~25Nm |
Thread code | C7:NPT1/2 | C7F:NPT1/2(Female) |
Dimensional drawing units:mm |
|
|