Product overview |
The HY-2001 economical pressure transmitter uses a diffusion silicon core as the pressure sensitive core, and a dedicated integrated circuit inside converts the sensor millivolt signal into a standard current signal. It can be directly connected to computer interface cards, control instruments, intelligent instruments, or PLCs for convenience. Long distance transmission can use current output mode. Small size, light weight, all stainless steel sealing structure, suitable for working in corrosive environments. This product is easy to install and has high vibration and impact resistance, and is widely used in process control, aviation, aerospace, automotive, medical equipment, HVAC and other fields.
Attention:
1. Do not misuse the file.
2. The information in this selection is for reference only and cannot be used as a product installation guide.
3. Complete installation, operation, and maintenance information is provided in the product manual.
4. Incorrect use can lead to danger and personal injury.
Specification |
arguments | |
Range range | -100kPa…0~35kPa…100MPa |
pressure datum | Gauge pressure, absolute pressure, sealing pressure |
accuracy | 0.5%FS |
arrearage | 0.1%FS |
repeatability | 0.1%FS |
Temperature drift | 35kPa:±2%FS(0℃~60℃) other:±1.5%FS(-20℃~85℃) |
response time | ≤1ms(上升到 90%FS) |
Overload pressure | Refer to the range selection table |
service life | ≥1×106 |
environment temperature | -20℃~85℃ |
medium temperature | -30℃~105℃ |
storage temperature | -40℃~125℃ |
EMC | noise immunity:IEC 61000-6-2, radiation:IEC 61000-6-3 |
insulation resistance | ≥100MΩ/500VDC(200MΩ/250VDC) |
vibration performance | sinusoid:20g, 25Hz~2kHz;IEC 60068-2-6 random:7.5grms, 5Hz~1kHz;IEC 60068-2-64 |
Impact resistance | impact:200g/1ms; IEC 60068-2-27 free falling body:1m; IEC 60068-2-32 |
level of protection | IP65 |
surge | IEC 61000-4-5 3 级 |
Electric resistance voltage | current output:500V/AC 1min voltage output:250V/AC 1min |
electrostatic | IEC 61000-4-2 4 级 |
Medium compatibility | Various media compatible with 316L stainless steel |
hexagonal | HEX27 |
hazardous rating | ExiaⅡCT6(只针对 4~20mA) |
Net weight | 150~180g |
Output and power supply | ||||||
code | B1 | B3 | B2 | B7 | B12 | B6 |
Output | 4~20mA | 0~5V | 1~5V | 0~10V | 1~10V | 0.5~4.5V R/M |
Power supply | 12~30VDC | 12~30VDC | 12~30VDC | 12~30VDC | 12~30VDC | 5VDC |
Electrical connection and wiring method | ||||
Connector code | J5:Big Hesman | J15:Hesmann direct lead | ||
Dimensional drawing units:mm |
|
| ||
protection grade | IP65 | IP65 | ||
Connection | 1:Power supply+(red line) 2:Current output (green line) | Red line: power supply Green line: current output | ||
Connection | Pin 1: Power supply+(red wire) | Red line: power supply+green line: common ground Yellow line: voltage output | ||
Connector code | J3:Direct lead | J4:Aerial insertion | ||
Dimensional drawing units:mm |
|
| ||
protection grade | IP65 | IP65 | ||
Wiring method | Red line: power supply+ Green line: current output | Pin 1: Power supply+(red wire) Pin 2: Current output (green line) | ||
Wiring method (3-wire voltage) | Red line: power supply+green line: common ground Yellow line: voltage output | Pin 1: Power supply+(red wire) Pin 2: Common ground (green line) Pin 3: Voltage output (yellow line) |
Selection of dampers
application
Cavitation, liquid hammer, and pressure peaks may occur in air or liquid systems with varying flow rates. For example, rapid closing of valves or starting and stopping of pumps. Even at relatively low operating pressures, these problems may occur at the inlet and outlet.
Medium conditions
In liquids containing particles, nozzle blockage may occur. Vertical installation of the transmitter can greatly reduce the risk of blockage, as the flow of fluid is limited to the initial stage of start-up, and the volume behind the nozzle is fixed, and the nozzle aperture is relatively large (1.2mm).
The effect of medium viscosity on response time is minimal, even if the viscosity reaches 100 CST, the response time will not exceed 4ms.